Circulation and Color Change
- Multiple heart sounds, rates, and intensities including normal, none, distant, systolic murmur, S3 and S4
- Chest compressions are measured and logged
- Blood pressure and oxygen saturation can be taken bilaterally using real equipment
- Korotkoff sounds audible between systolic and diastolic pressures
- Cyanosis and vital signs respond to physiologic condition and interventions
- Bilateral carotid, radial, brachial, femoral, posterior tibial and pedal pulses operate continuously. Pulse strengths vary with Susie’s blood pressure and pulses are synchronized with the ECG
Venous Access
- Bilateral IV training arms
- IM sites on shoulders and thighs
- Draw blood from finger stick
Active Eyes
- Open and close
- Select blink rate
- Reactive pupils
- Select pupillary response to light
- Program “blown” pupil
Conduct breast examinations and teach BSE techniques
- Proprietary silicone breast inserts
- Interchangeable left breasts include
- Fibrosystic disease (chronic mastitis)
- Benign tumor with stalk
- Giant sarcoma
- Scirrhus carcinoma
- Carcinoma in milk duct
- Right breast contains 8, 10, 16, and 20mm lumps for BSE